Ultrafiltration for Industrial Water Treatment

A bundle of hollow fibers of an ultrafiltration membrane in a module cross-section

Water treatment technologies

Ultrafiltration for Industrial Water Treatment

Consistent water quality and equipment protection: the membrane retains suspended solids, colloids and bacteria without coagulants or settling tanks. Our projects range from a hotel complex to a community station for 1,000–2,000 m³/day.

  • Pores 0.01–0.1 µm
  • Backwash takes 5–10 minutes
  • In-house laboratorywater analysis and testing
  • 1,760+ completed projectsZIKO experience since 1993
  • Up to 5-year warrantyon solutions and equipment, under the contract terms
  • Service across Ukrainetechnical support and field service crews

Choosing a technology

Ultrafiltration or another treatment technology?

UF removes suspended solids and colloids and reduces turbidity and microbiological contamination. It does not reduce salts or hardness. UF is installed as a separate stage or as part of a combined treatment scheme.

What needs removingMechanical filtrationUltrafiltrationReverse osmosisUV disinfection
Mechanical impuritiessand, scale flakes, particles from 20 µmremovesyes, but mechanical filtration before UF is mandatoryno: pretreatment neededno
Turbidity and colloidsfine suspended solids, clay, oxidized ironpartly: down to 20 µmremovesno: feed turbidity must be ≤ 0.3 NTUno
Microbiological contaminationbacteria and protozoanoretains physicallyretains, if the membranes are intactinactivates, but does not remove
Salts and hardnessmineralization, scalenono: composition stays the sameremovesno
What goes to draincontinuous flow or batch dischargebackwash waterbackwash waterconcentrate, 15–30% of the feed waternothing

The result depends on the raw water, the equipment and the operating mode.

How we choose the technology

  • Raw water: laboratory analysis and source type.
  • Treated water requirements: what the water is for.
  • Capacity: m³/h and m³/day.
  • Operating mode: automation, continuity of supply.
  • Costs: capital and operating, over the entire service life.

We run the analysis in our own laboratory and, if needed, process trials.

Industries where ultrafiltration can be part of the scheme

How it works

How industrial ultrafiltration works

A UF module is a bundle of thousands of hollow fibers. The membrane separates out suspended solids, colloids and bacteria.

Water path through the module

Waterafter mechanical filtration
UF module
pores 0.01–0.1 µm
Filtrateno suspended solids or bacteria

Under pressure, water passes through the porous wall into the fiber, while contaminants stay outside.

What is retained does not build up in the module: the backwash automatically flushes it to drain

The modules ZIKO uses have fibers 1.3 or 0.7 mm in diameter. The diameter determines how the module handles turbid water: thicker fibers clog less, thinner fibers fit more membrane area into the same housing.

A glass of cloudy water with iron and sediment — water before treatment

Water before the membrane: what UF retains

  • Suspended solids and turbidity, fine mechanical impurities
  • Colloids and high-molecular-weight organics
  • Bacteria and protozoa
  • Iron and other metals in particulate form
A glass of clear water — water after treatment

Filtrate after UF

  • No suspended solids or bacteria: goes to the consumer or to the next stage
  • Same mineral composition: the membrane does not change dissolved salts or hardness

What passes through needs another stage

  • Dissolved salts, hardness and salinity: softening or RO
  • Dissolved iron and manganese: iron removal before the membrane
  • Nitrates and silica: RO
  • Viruses: only partly, depending on the membrane; where a guarantee is needed, disinfection is installed after UF

Applications

Ultrafiltration in ZIKO combined solutions

From local systems to municipal water supply stations. UF almost never stands alone: mechanical filtration comes before it, and disinfection or RO after it.

Pore size: from mechanical filtration to RO
  1. Mechanical filtrationsand, scale flakes, coarse solids130 · 100 · 20 µm
  2. Ultrafiltrationcolloids, organics, bacteria0.01–0.1 µm
  3. Nanofiltrationsome salts, multivalent ions0.001–0.002 µm
  4. Reverse osmosisdissolved salts, desalination< 0.0001 µm

Logarithmic scale: each division is a hundred times finer than the previous one.

  • Mechanical filtration → UF → disinfection

    01. Surface water

    Clear water with no suspended solids or bacteria, without coagulants or settling tanks

    After rain and floods, the turbidity of rivers and reservoirs rises several times over. The membrane needs no chemical dose readjustment: only the cleaning frequency changes.

    For municipal, domestic and industrial needs

  • Mechanical filtration → UF → reverse osmosis

    02. Industrial plants

    Turbidity ≤ 0.3 NTU and SDI₁₅ ≤ 5, recommended < 3: ZIKO requirements for RO feed water

    UF works as a separate stage or as part of a combined scheme. It removes suspended solids and colloids and protects process equipment and the more expensive, more sensitive RO membranes.

    Iron and manganese are removed before UF

  • Treated effluent → UF → disinfection or RO

    03. Water reuse — ZIKO 360

    Water for technical needs from treated wastewater

    We polish effluent after the treatment plant and return the water to production. The membrane removes the suspended solids and microorganisms left after treatment. The result: less fresh water and less discharge.

    The scheme depends on the effluent composition after treatment

Cleaning, automation and service

Ultrafiltration membranes: long service life without frequent replacement

Contaminants build up on the membrane and increase resistance. Automatic backwashes remove them, with chemical cleaning when needed. Cleaning frequency is set by the differential pressure across the module, not by the calendar.

  • Automatic backwashing

    Remove fouling and maintain capacity without manual intervention.

  • Monitoring and automation

    Parameter monitoring, mode control, protective algorithms, integration with the plant SCADA.

  • Membrane life

    The membranes are designed to last for years. We replace them based on actual condition, not on a schedule.

  • ZIKO service

    Commissioning, automation setup, scheduled maintenance.

Cleaning schedule

Backwash
5–10 minwith treated water, about 1.5 bar
Air scouring or chemically enhanced backwash in operation
10–20 minfor organics and silicates that are hard to wash off
Full chemical cleaning
1–2.5 hfor heavy fouling

What the site needs

Mechanical pretreatment
mandatoryotherwise the fibers clog quickly
Inlet pressure to the equipment
at least 3 bar
Backwash water disposal
drain or sewer
Where the backwash water goes

After backwashing, water goes to drain with everything the membrane retained: suspended solids, colloids, microorganisms. We include its volume and disposal in the design together with the capacity. This determines how much raw water must be fed.

Experience

Industrial ultrafiltration: ZIKO projects of different scales

We handle the whole project: calculations, supply, installation, commissioning, staff training, warranty and service support.

  • Community · 1,000–2,000 m³/day

    Containerized ultrafiltration station

    • The technology was chosen based on a laboratory analysis of the raw water
    • The calculation took into account capacity, hydraulic conditions and automation
  • Hotel and leisure complex · river water

    Ultrafiltration up to 150 m³/day

    • The scheme was designed for the river water quality and its seasonal fluctuations
    • The equipment sits in a plant room and is integrated into the complex’s utilities
  • Reverse osmosis · juice production

    Membrane system — 30 m³/h

    • Water for the product, steam generators and heating
    • The same pretreatment, cleaning and service requirements as for ultrafiltration
    Project details →

The capacities shown are examples, not limits: we size the system for your demand in m³/h and m³/day.

Need ultrafiltration for your site?Send us your water analysis and required capacity — we’ll size the system and estimate the capital and operating costs.

Get an engineering estimate

Cost

What determines the cost of ultrafiltration

We calculate the cost for each project from the water analysis, the required capacity and the treated water requirements.

What drives the figure

  • Raw water. Turbidity, suspended solids, colloids, organics and seasonal fluctuations. They determine whether pretreatment is needed.
  • Capacity and redundancy. Consumption schedule, peaks, operating mode, acceptable interruptions. If needed, we add standby equipment.
  • Scope of supply and automation. Membranes, pumps, monitoring, SCADA integration. And what comes after UF: disinfection or RO.
  • Water balance and operation. Water for cleaning, energy, chemicals, maintenance, backwash water disposal.
We calculate the total cost: CAPEX + OPEX

CAPEX: equipment, automation, design, installation, commissioning.

OPEX: electricity, water for cleaning, chemicals, maintenance, membrane replacement.

Our goal is a well-justified configuration, not the lowest upfront price. We are not tied to any single equipment manufacturer.

Compare it with a chemical treatment scheme, not with another membrane

The alternative to UF for surface water is clarification by coagulation with a settling tank and filters. Its cost structure is different: chemicals, structure volume, sludge. So for the same source, it is worth calculating both options.

FAQ

Ultrafiltration: answers to common questions

Didn’t find your question? Ask an engineer using the form below.

Cross-section of an ultrafiltration module: a bundle of hollow fibers
Ultrafiltration or reverse osmosis?

UF retains suspended solids, colloids, bacteria and, depending on the membrane, some viruses. Dissolved salts, including hardness salts, pass through it. RO reduces dissolved salts and itself needs clean feed water. That is why UF is installed as a separate stage or ahead of RO.

Does ultrafiltration replace disinfection?

Partly. The membrane is a physical barrier to bacteria, but it has no effect in the network downstream and only partly retains viruses. Whether you need disinfection after UF depends on what the water is for and how it is stored and distributed.

Does UF remove iron?

Only oxidized iron, in particulate form. Dissolved iron and manganese pass through the membrane, so they are removed by iron removal upstream.

How often should the membrane be cleaned?

Cleaning is automatic, and its frequency is set by the differential pressure across the module. A backwash with treated water takes 5–10 minutes. Air scouring or a chemically enhanced backwash in operation takes 10–20 minutes. A full chemical cleaning for heavy fouling takes from 1 to 2.5 hours.

How long do ultrafiltration membranes last?

For years. Automatic cleaning and scheduled maintenance keep their performance stable. A membrane is replaced based on its actual condition, judged by an integrity test and operating data.

Do you need UF for well water?

Usually not. Groundwater is mostly clear, and its typical problems (iron, manganese, hardness) are not solved by ultrafiltration. UF makes sense where the water is turbid or microbiologically unstable. The final decision rests on the water analysis, not the source type.

Can ultrafiltration produce drinking water?

UF is an important stage in drinking water treatment: it removes suspended solids and reduces microbiological contamination. It does not remove dissolved chemical impurities, so on its own it only works with suitable water. We design the scheme from the analysis and the applicable drinking water standards.

Size an ultrafiltration system

Send us your water analysis, required capacity and treated water requirements. We’ll select the scheme and estimate CAPEX and OPEX. No analysis? We’ll do one in our laboratory. Consultation and preliminary estimate are free.