Iron and manganese removal from water

Cross-section of an iron removal filter column: a layer of oxidized iron above black catalytic media, sand and gravel

Industrial water treatment technologies

Iron and manganese removal from water

We remove iron, manganese and hydrogen sulfide for plants, water utilities, residential and commercial sites. We design the scheme around your water analysis, the capacity you need and your treated water requirements.

  • Fe ≤ 0.2 mg/L at an operating site
  • From 20 to 420 m³/h at completed sites
  • In-house laboratorywater analysis and testing
  • 1,760+ completed projectsZIKO experience since 1993
  • Up to 5-year warrantyon solutions and equipment, under the contract terms
  • Service across Ukrainetechnical support and field service crews

What affects water quality

Iron, manganese and hydrogen sulfide are the most common contaminants in groundwater

They leave sediment and deposits in pipes and equipment, spoil the product and drive up repair costs. Dissolved iron is clear, so the problem is judged by analysis, not by eye.

  • Iron

    Can be dissolved, colloidal or insoluble. Leaves rust-colored deposits on equipment, stains on the product and sediment in pipes.

  • Manganese

    Even at low concentrations it causes black and dark brown stains. It oxidizes less readily than iron, so a filter that handles iron well can still let manganese through.

  • Hydrogen sulfide

    Smells of rotten eggs and often comes with iron. Not regulated in Ukraine; the EU limit is 0.03 mg/L. The same oxidation scheme removes it.

  • Suspended solids after oxidation

    Oxidized iron is a suspension that has to be captured. Without filtration, the sediment simply travels on through the network.

Iron removal or another technology

What needs removingIron removalCombined treatmentSofteningReverse osmosis
Irondissolved and oxidizedremovesremovesno: fouls the resinno: inlet ≤ 0.05 mg/L
Manganesedark stains, sedimentremovesremovesnono: inlet ≤ 0.05 mg/L
Hydrogen sulfiderotten egg smellcatalytic mediadepends on the schemenono
Hardnessscalenoremovesremovesremoves
What goes to draincontinuous flow or batch dischargebackwash water with sludgespent salt regeneration brinespent salt regeneration brineconcentrate, 15–30% of feed water

Combined treatment removes more than a single stage, but it regenerates with salt. So the choice between them also depends on the wastewater, not just on water quality — see the poultry processing example below. The final decision rests on the water analysis.

Industries where iron removal is part of the scheme

How it works

How iron and manganese removal systems work

First we convert dissolved iron and manganese into an insoluble form, then we capture the suspended solids in the media bed. We choose the oxidation method and the media based on the analysis — we do not use one-size-fits-all schemes.

Column cross-section · example from a water utility in the Lviv region
Raw waterdissolved iron, manganese, hydrogen sulfide
Catalytic media based on manganese oreoxidizes and captures iron, manganese, hydrogen sulfide
Silica-based mediacaptures suspended solids and oxidized iron
Treated waterto the network or the next stage

The make-up and ratio of the layers are matched to the water analysis — this is part of ZIKO’s engineering method.

Column operating cycle

Step 01 of 04

Oxidation

Dissolved iron turns into an insoluble form. The oxidation method depends on the water composition.

A glass of water in which dissolved iron oxidizes into rust-colored flakes
No classic aeration

ZIKO does not use schemes with compressors, ejectors and aeration towers. We select the technology and media for the actual water composition.

Step 02 of 04

Filtration

The media bed captures the suspended solids.

A jar of black catalytic media

Step 03 of 04

Backwash

A reverse flow flushes the sediment to drain — triggered by the controller.

A glass of backwash water with rust-colored iron sediment

Step 04 of 04

Back in service

The column returns to the cycle; with two columns and an alternator, supply never stops.

A glass of clear water after iron removal

Choosing the technology

Same iron concentration — different engineering solutions

With the same iron and manganese levels, water from different sources may need different technologies. There is no universal threshold of “one technology up to this concentration, another above it”.

  • Form of iron

    Dissolved or already oxidized — this decides how much of the work falls on oxidation and how much on filtration.

  • Manganese

    Needs different process conditions than iron. The scheme is designed for both elements at once, otherwise manganese gets through.

  • Hydrogen sulfide

    Causes odor and escapes from the sample quickly — so how and when the sample was taken matters.

  • pH

    Affects how quickly and completely iron and manganese oxidize.

  • Organics and oxidizability

    Organic compounds keep iron in solution and hinder oxidation.

  • What the wastewater can contain

    Mineralization and acceptance conditions determine what you can use to regenerate the media.

  • Water source

    A well, the municipal mains or a surface source, plus seasonal changes in composition.

  • Capacity and operating mode

    Demand in m³/h and m³/day, peak consumption, reserve and continuity of supply.

Two measuring cylinders: rust-colored water with iron before treatment and clear water after
A wrong technology can cost more than the system itself

The water comes out unstable, and the equipment wears out and needs rework. That is why we check difficult cases in our own lab: we test the media on a sample of your water before you buy any equipment.

Iron removal goes first after mechanical filtration

Otherwise iron will foul the softener resin and the membranes. Reverse osmosis has a strict limit — no more than 0.05 mg/L of iron at the inlet.

Completed projects

Iron removal already at work

From a slaughterhouse to a city water utility: systems of 20–420 m³/h for wells, municipal mains and surface sources. Iron at the inlet — up to 24 mg/L.

City water utility · Volyn region

Iron removal — 420 m³/h

Water for the city’s central supply: drinking and household needs.

Iron removal · 80 m³/h

Raw water
Iron removal filters
Fe ≤ 0.2mg/L

equipment washing, poultry chilling

Media regeneration

With brine — rejectedeffluent up to 25,000 mg/L, chlorides, fails discharge requirements
With water — chosenno salts in the effluent, lower load on the treatment plant · running since 2018

Poultry processing · slaughterhouse · since 2018

Iron removal for a slaughterhouse — 80 m³/h

80 m³/h1,920 m³/day
24 → ≤ 0.2iron, mg/L: inlet and outlet
since 2018running with no scheme changes

Salt regeneration was rejected at the design stage: the effluent would not have met discharge limits. Water regeneration costs more upfront but less to run.

  • ZIKO containerized water treatment module on site before installation

    Small town · Lviv region

    Modular containerized plant — 35 m³/h

    • Well water: iron removal, disinfection and reverse osmosis
    • Equipment housed in a container module
  • Iron removal columns with control valves in the plant room of a healthcare facility

    Healthcare facility · Lviv region

    Iron removal for mains water — 20 m³/h

    • Water from the municipal mains for the hospital’s drinking and household needs
  • City water utility · Volyn region

    Iron removal and disinfection — 50 m³/h

    • Iron: 2.2 → below 0.2 mg/L
    • Self-cleaning filters → sodium hypochlorite → catalytic iron removal
  • Leisure resort · Lviv region

    Complete water treatment — 60 m³/h

    • Iron removal, disinfection and nanofiltration
    • Drinking and household water for the resort
  • Iron removal columns with an alternator at a water utility plant in the Lviv region

    City water utility · Lviv region · surface source

    Water utility in the Lviv region

    • Alternator: the columns run in turn, so supply never stops for backwash
    • Catalytic media based on manganese ore: iron, manganese, hydrogen sulfide
    • Self-cleaning mechanical filter before iron removal, hypochlorite dosing after

Iron above the limit in your analysis?Send us the lab report and the capacity you need — a ZIKO engineer will select an iron removal scheme and tell you where to discharge the backwash water.

Get an engineering estimate

Operation

Automation does most of the work

What the system does on its own

Backwash
on schedule or by volumetriggered by the controller
Columns
in turn, via an alternatorsupply never stops
Controller
2 to 6 filtersshows the time to the next regeneration
Alarms
warn about deviationscan send data to the control room if needed

What needs a person

Iron and manganese checks
in a sample after the filter
Reagent
topping upif the scheme uses reagents
Backwash water consumption
watch for growththe first sign the media is wearing out
Where the backwash water goes

Unlike RO concentrate, it carries a lot of suspended solids — iron and manganese compounds.

  • Discharged to the industrial sewer
  • Settled to separate the sludge
  • Treated on site, with part of the water reused

Whether it can be discharged depends on its composition and the acceptance conditions at your site.

Service after start-up

We commission the system, train your staff and provide warranty and post-warranty service: we diagnose the equipment, check treatment quality and adjust operating modes.

Cost

Cost of iron removal: it is not just the equipment price

We price the system for your site — based on the water analysis, capacity and treated water requirements. We compare not only the equipment cost but also the costs over its whole service life.

What drives the cost

  • Water composition: how many stages and which media you need
  • Capacity in m³/h and m³/day, operating mode, peaks and reserve
  • Treated water requirements: drinking, household or process
  • Level of automation and remote monitoring
  • How to regenerate the media and where to discharge the backwash water

We calculate the total cost of ownership

  • Capital costs — equipment, automation, installation and commissioning
  • Operating costs — backwash water, reagents (if the scheme uses them), electricity, service
  • Life cycle — equipment life, maintainability, upgrades
ZIKO installers assembling pipework next to the filter columns
Get a preliminary cost estimate

Send us your water analysis, capacity and treatment requirements — an engineer will review the data and suggest the next steps.

Get a preliminary estimate

FAQ

Frequently asked questions about iron and manganese removal

Didn’t find your question? Ask an engineer using the form below.

A white safety helmet, goggles and an engineer’s notebook
Tap water looks clear — why remove iron?

In groundwater, iron is dissolved and invisible when the water is drawn. It oxidizes with oxygen from the air later — in a tank, a pipeline or the product. That is why you judge by a lab report on a fresh sample, not by color.

Can water with very high iron content be treated?

Yes, with the right technology. At a poultry processing plant, an 80 m³/h system reduces iron from 24 mg/L to ≤ 0.2 mg/L.

Why does a filter hold iron but let manganese through?

Manganese oxidizes under different conditions and more slowly than iron. A scheme designed only for iron does not create those conditions. The fix is the right media and operating mode, not a bigger column.

Do you use aeration?

Not classic schemes with compressors, ejectors and aeration towers. We select the technology and media for the water composition, and we check difficult cases in the lab on a sample before you buy any equipment.

Do I need a water analysis?

Yes, the technology cannot be chosen without it. If you do not have one, we will do it in our lab. The sample must be fresh and delivered as quickly as possible: iron settles out in air, and hydrogen sulfide escapes quickly.

Does the system need a full-time operator?

No. The system backwashes the filters and monitors operating parameters on its own. A person is needed for scheduled maintenance and periodic water quality checks.

Get your iron removal system calculated

We will match the system to your water composition, capacity and treatment requirements. No analysis yet? We will do it in our lab. The consultation and preliminary estimate are free.

Phone: +38 095 93 21 273

Water sample bottles for laboratory analysis

Where to go next

Related technologies

Water sources

  • Boreholes and groundwater sources